Property Inspection Report
Client(s): John Goodman & Janice Giddens
Property address: 714 W.3rd. Ave.
Albany, GA
Inspection date: 5-9-2008
This report published on 5/13/2008 10:16:21 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Electric
Plumbing / Fuel Systems
Water Heater
Heating
Cooling / Heat Pump
Fireplaces / Stoves / Chimneys
Bathrooms / Laundry / Sinks
Kitchen
Interior Rooms / Areas
 
General Information Return to table of contents
Report number: 08150
Report number: 08150
Time started: 3 pm
Time started: 3 pm
Time finished: 6 pm
Time finished: 6 pm
Inspector: DM
Inspector: DM
Present during inspection: Client, Property owner, Tenant, Realtor
Present during inspection: Client, Property owner, Tenant, Realtor
Client present for discussion at end of inspection: Yes
Client present for discussion at end of inspection: Yes
Weather conditions: Clear
Weather conditions: Clear
Temperature: Hot
Temperature: Hot
Ground condition: Dry
Ground condition: Dry
Inspection fee: 250.00
Inspection fee: 250.00
Type of building: Duplex
Type of building: Duplex
Number of residential units inspected: 2
Number of residential units inspected: 2
Age of building(s): 70+
Age of building(s): 70+
Source for building age: Realtor
Source for building age: Realtor
Front of building faces: East
Front of building faces: East
Main entrance faces: East
Main entrance faces: East
Occupied: Yes, Furniture or stored items were present
Occupied: Yes, Furniture or stored items were present
Additions and modifications: Apartment in back
Additions and modifications: Apartment in back
Source for additions and modifications: Realtor
Source for additions and modifications: Realtor


1)   Some wall and floor surfaces were obscured by furniture and couldn't be fully evaluated.
2)   Some wall and floor surfaces were obscured by furniture and couldn't be fully evaluated.
 
Grounds Return to table of contents
The following items are excluded from this inspection: Outbuildings, Fences and gates, Shed
The following items are excluded from this inspection: Outbuildings, Fences and gates, Shed
Condition of fences and gates: Appeared serviceable
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wood, Chain link
Fence and gate material: Wood, Chain link
Site profile: Minor slope
Site profile: Minor slope
Condition of sidewalks and/or patios: Appeared serviceable
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Condition of decks, porches and/or balconies: Appeared serviceable
Condition of decks, porches and/or balconies: Appeared serviceable
Condition of guardrails: Required repairs, replacement and/or evaluation (see comments below)
Condition of guardrails: Required repairs, replacement and/or evaluation (see comments below)
Deck, porch and/or balcony material: Masonry
Deck, porch and/or balcony material: Masonry
Condition of exterior stairs: Appeared serviceable
Condition of exterior stairs: Appeared serviceable
Condition of handrails: Required repairs, replacement and/or evaluation (see comments below)
Condition of handrails: Required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Masonry
Exterior stair material: Masonry
3)   Handrails at one or more flights of stairs were loose. This is a safety hazard. A qualified person should repair or replace as necessary and as per standard building practices. at front door

Photo 1  
FRONT
 

4) Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from the building exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the building exterior.
5) Trees were in contact with or were close to the building in one or more areas. Damage may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

Photo 15  
TREES TOUCHING ROOF

Photo 16  
TREES TOUCHING ROOF

Photo 19  
TREES TOUCHING ROOF

Photo 21  
TREES TOUCHING ROOF, CLEAN GUTTERS

6)   Some fence sections were obscured by vegetation and couldn't be fully evaluated.
 
Exterior / Foundation Return to table of contents
Condition of wall covering: Appeared serviceable
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Apparent wall structure: Wood frame
Wall covering: Brick veneer
Wall covering: Brick veneer
Condition of foundation and footings: Appeared serviceable
Condition of foundation and footings: Appeared serviceable
Foundation type: Crawlspace
Foundation type: Crawlspace
Foundation material: Not determined
Foundation material: Not determined
Footing material: Masonry
Footing material: Masonry
Condition of floor substructure: Appeared serviceable
Condition of floor substructure: Appeared serviceable
Pier or support post material: Masonry
Pier or support post material: Masonry
Beam material: Solid wood
Beam material: Solid wood
Floor structure: Solid wood joists
Floor structure: Solid wood joists
Condition of crawl space: Appeared serviceable
Condition of crawl space: Appeared serviceable
Crawl space inspection method: Partially traversed
Crawl space inspection method: Partially traversed
Ventilation: Appears serviceable
Ventilation: Appears serviceable
7) Rot or water damage was found at one or more sections of trim, window sills, fascia. A qualified person should evaluate and repair as necessary. All rotten wood should be replaced.

Photo 7  
SMALL HOLE ON WINDOW IN FRONT, NEEDS CAULKING
 

8)   Some sections of siding and/or trim were deteriorated. A qualified person should evaluate and repair, replace or install siding or trim as necessary.

Photo 6  
NEEDS CAULKING

Photo 8  
CLEAN OFF ROOF OF DEBRIS, AND CAULK IN SOME PLACES

Photo 18  
CLEAN VALLEYS OF DEBRIS
 

9)   Minor cracks or deterioration were found in one or more sections of brick veneer. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar to prevent water intrusion and further deterioration in the future.

Photo 10  
MINOR CRACK IN BRICK ALL AROUND

Photo 23  
MINOR CRACKS

10) Caulk was deteriorated in some areas. For example, around windows, around doors. A qualified person should repair or replace as necessary. For more information, visit:
http://www.reporthost.com/_docs/FPL_Caulking_Ins_Outs.pdf

11) One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including hydraulic cement, resilient caulks and epoxy sealants.
12) Caulk was deteriorated in some areas. For example, around windows, around doors. A qualified person should repair or replace as necessary. For more information, visit:
http://www.reporthost.com/_docs/FPL_Caulking_Ins_Outs.pdf

13)   Some crawl space sections were not evaluated due to lack of access from the following conditions: height under 18 inches, ducts or pipes blocking.

Photo 49  
DUCTS NEED TO BE RE WRAPPED
 

14)   Some exterior wall sections were obscured by vegetation and couldn't be fully evaluated.
 
Roof / Attic Return to table of contents
Condition of roof structure: Appeared serviceable
Condition of roof structure: Appeared serviceable
Roof type: Hipped
Roof type: Hipped
Age of roof surface(s): UNK
Age of roof surface(s): UNK
Source for building age: Inspector's estimate 8 -10 yrs0
Source for building age: Inspector's estimate 8 -10 yrs
Roof inspection method: Viewed from ground with binoculars
Roof inspection method: Viewed from ground with binoculars
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Roof surface material: Asphalt or fiberglass composition shingles
Apparent number of layers of roof surface material: One
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Required repair, replacement and/or evaluation (see comments below)
Condition of exposed flashings: Required repair, replacement and/or evaluation (see comments below)
Condition of gutters, downspouts and extensions: Required repair, replacement and/or evaluation (see comments below)
Condition of gutters, downspouts and extensions: Required repair, replacement and/or evaluation (see comments below)
Gutter and downspout material: Metal
Gutter and downspout material: Metal
Gutter and downspout installation: Partial
Gutter and downspout installation: Partial
Condition of attic: Appeared serviceable
Condition of attic: Appeared serviceable
Attic inspection method: Traversed
Attic inspection method: Traversed
Roof structure type: Rafters
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Ceiling structure: Ceiling beams
Ceiling insulation material: Fiberglass loose fill
Ceiling insulation material: Fiberglass loose fill
Ceiling insulation depth: 3 inches
Ceiling insulation depth: 3 inches
Ceiling insulation rating: > R-30
Ceiling insulation rating: > R-30
Vapor retarder: Not determined
Vapor retarder: Not determined
Roof ventilation: Appears serviceable
Roof ventilation: Appears serviceable
15) Some "rubber boot" flashings were torn. Leaks may occur as a result. A qualified contractor should replace flashings where necessary.

Photo 2  
FLASHING IN NEED OF REPAIRS
 

16)   The ceiling insulation in some areas of the attic was uneven. This may result in increased heating or cooling costs due to decreased energy efficiency. A qualified person should repair, replace or install insulation as necessary. For more information, visit:
http://www.eere.energy.gov/consumer/tips/insulation.html

Photo 47  
INSULATION UNEVEN IN ATTIC
 

17)   The ceiling insulation in some areas of the attic was uneven. This may result in increased heating or cooling costs due to decreased energy efficiency. A qualified person should repair, replace or install insulation as necessary. For more information, visit:
http://www.eere.energy.gov/consumer/tips/insulation.html

18)   No insulation or weatherstrip was installed at one or more attic access hatches. Recommend installing insulation and weatherstrip at hatches where missing for better energy efficiency. For more information, visit:
http://www.reporthost.com/_docs/atticaccess.pdf

19) Debris had accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the building exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.
20) Debris such as leaves, needles, seeds, etc. had accumulated on the roof. This is a conducive condition for wood destroying insects and organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.

Photo 12  
CLEAN VALLEYS OF DEBRIS
 

21)   Because of the roof covering type, roof configuration, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.
 
Electric Return to table of contents
Electric service condition: Appeared serviceable
Primary service type: Overhead
Number of service conductors: 2
Service voltage (volts): 120
Service amperage (amps): 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Aluminum
Main disconnect rating (amps): 200
System ground: Cold water supply pipes
Condition of main service panel: Appeared serviceable
Condition of sub: Appeared serviceable
Location of main service panel #A: Building exterior
Location of sub-panel #B: Apartment
Location of main disconnect: Breaker at top of main service panel
Branch circuit wiring type: Non-metallic sheathed
Condition of branch circuit wiring: Serviceable
Solid strand aluminum branch circuit wiring present: Not determined
Condition of smoke detectors: Appeared serviceable
Smoke detectors present: Yes
Smoke detector power source: Battery
22)   The dead front to panel #A was installed so it was not flush with the surface of the panel box and disconnect devices. Gaps existed, resulting in exposed wiring. This is a safety hazard due to the risk of shock. A qualified person should evaluate and repair as necessary

Photo 41  
ELECTRICAL PANEL OUTSIDE
 

23)   Many open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used. Just be sure you use a surge protector
    24)   One or more electric receptacles at the kitchen, bathroom(s) had no visible ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. Recommend having a qualified electrician evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
    http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf The one in the main bath under sink is not wired right.

    25)   One or more outdoor electric receptacles appeared to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all outdoor receptacles within six feet six inches of ground level have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    26)   Energized equipment was exposed at panel #B due to missing closure covers. This is a safety hazard due to the risk of shock. A qualified person should repair as necessary. This was in the apartment
    27)   Smoke detectors were missing from bedrooms, from hallways leading to bedrooms. Additional smoke detectors should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, in each bedroom, and one each level of the building. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    Electric service condition: Appeared serviceable
    Primary service type: Overhead
    Number of service conductors: 2
    Service voltage (volts): 120
    Service amperage (amps): 200
    Primary service overload protection type: Circuit breakers
    Service entrance conductor material: Aluminum
    Main disconnect rating (amps): 200
    System ground: Cold water supply pipes
    28)   The service drop wires were in contact with trees or vegetation. The utility company should prune or remove trees as necessary to prevent straining or abrading the service drop wires.

    Photo 9  
    TREES TOUCHING HOME
     
     
    Plumbing / Fuel Systems Return to table of contents
    Condition of service and main line: Appeared serviceable
    Location of main water meter: front
    Location of main water shut: front
    Water service: Public
    Service pipe material: Galvanized steel
    Condition of supply lines: Appeared serviceable
    Supply pipe material: Galvanized steel
    Condition of waste lines: Appeared serviceable
    Waste pipe material: Plastic, Cast iron
    Condition of fuel system: Appeared serviceable
    Location of main fuel shut: at meter
     
    Water Heater Return to table of contents
    Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
    Condition of water heater: Table top model
    Type: Tank
    Estimated age: Unk.
    Energy source: Electricity
    Capacity (in gallons): Not determined
    Water temperature (degrees Fahrenheit): 123
    29)   The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be near this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    30)     DID NOT DO TO CONTER TOP INSTALED ON UNIT
     
    Heating Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
    Condition of heating system: Appeared serviceable
    Location of heating system: RIGHTSIDE
    Heating type: Forced air
    Fuel type: Natural gas
    Manufacturer: Carrier
    Last service date: UNK
    Model: see pic
    Source for last service date: Unk
    Condition of venting system: Appeared serviceable
    Condition of distribution system: Appeared serviceable
    Distribution system: Ducts and registers
    Condition of controls: Appeared serviceable
    Condition of air filters: Appeared serviceable
    Location of air filters: Behind return air grill
    31)   Because of the age and/or condition of this furnace, recommend that a qualified heating and cooling technician inspect the heat exchanger and perform a Carbon Monoxide test when it's serviced.
    32)   The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
    33)   Some of the insulation on distribution ducts in the crawl space was damaged, deteriorated. A qualified person should evaluate and replace or repair as necessary for better energy efficiency.
     
    Water Heater Return to table of contents
    Condition of water heater: Table top model
    Type: Tank
    Estimated age: Unk.
    Capacity (in gallons): Not determined
    Water temperature (degrees Fahrenheit): 123
    34)   The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be near this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
     
    Cooling / Heat Pump Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
    Condition of cooling system and/or heat pump: Appeared serviceable
    Location: Right side
    Type: Packaged unit
    Estimated age: 8-10 yrs
    Approximate tonnage: 3
    Manufacturer: Carrier
    Condition of distribution system: Appeared serviceable
    Condition of controls: Appeared serviceable
    Condition of air filters: Appeared serviceable
    Location of air filters: Behind return air grill
    35)   The cooling fins at the AC condenser were dirty. A qualified person should clean fins as necessary.
    36)   Most of the insulation on distribution ducts in the crawl space was deteriorated. A qualified person should evaluate and replace or repair as necessary for better energy efficiency.
    37)   The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
     
    Heating Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
    Fuel type: Natural gas
    Manufacturer: Carrier
    Source for last service date: Unk
    Condition of venting system: Appeared serviceable
    Condition of distribution system: Appeared serviceable
    Distribution system: Ducts and registers
    Condition of controls: Appeared serviceable
    Condition of air filters: Appeared serviceable
    Location of air filters: Behind return air grill
    38)   Because of the age and/or condition of this furnace, recommend that a qualified heating and cooling technician inspect the heat exchanger and perform a Carbon Monoxide test when it's serviced.
    39)   The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html

    Photo 17  
    COVER OVER A/C UNIT NEED TO BE REPAIRED

    Photo 35  
    DUSTY RETURN AIR VENT
     
    Cooling / Heat Pump Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
    Condition of cooling system and/or heat pump: Appeared serviceable
    Location: Right side
    Type: Packaged unit
    Estimated age: 8-10 yrs
    Approximate tonnage: 3
    Manufacturer: Carrier
    Condition of distribution system: Appeared serviceable
    Condition of controls: Appeared serviceable
    Condition of air filters: Appeared serviceable
    Location of air filters: Behind return air grill
    40)   The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
     
    Fireplaces / Stoves / Chimneys Return to table of contents
    Location #A: living room
    Location #B: bedroom / master ?
    Fireplace type: Masonry
    Fuel type: Wood
    Condition of chimneys: Required repair, replacement and/or evaluation (see comments below)
    Chimney type: Masonry
    Location #A: living room
    Location #B: bedroom / master ?
    Fireplace type: Masonry
    Fuel type: Wood
    Condition of chimneys: Required repair, replacement and/or evaluation (see comments below)
    Chimney type: Masonry
    41)   The inspector found cracks at the fireplace at location #A. Recommend having a qualified contractor evaluate and repair as necessary.

    Photo 26  
    FIREPLACE FLOOR CRACKED
     

    42)   The damper at location #A, B was inoperable. A qualified contractor should evaluate and repair as necessary.

    Photo 27  
    DAMPER HANDLE WILL NO OPEN
     

    43)   The chimney at location #A, B showed moderate evidence of . Chimney(s) may need bracing, or in some extreme cases, removal. A qualified contractor should evaluate and repair or replace as necessary.
    44)   All solid fuel burning appliances (woodstoves and fireplaces, etc.) should be inspected annually by a qualified chimney service contractor, cleaned and repaired as necessary.
     
    Kitchen Return to table of contents
    Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Appeared serviceable
    Condition of dishwasher: Appeared serviceable
    Condition of range, cooktop: Appeared serviceable
    Range, cooktop type: Electric
    45)   Caulk was missing where counters met back splashes. A qualified person should repair as necessary.
     
    Bathrooms / Laundry / Sinks Return to table of contents
    Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
    Location #A: Main
    Location #B: apartment
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Appeared serviceable
    Condition of toilets: Appeared serviceable
    Condition of bathtubs and related plumbing: Required repair, replacement and/or evaluation (see comments below)
    Condition of shower(s) and related plumbing: Appeared serviceable
    Condition of ventilation systems: Required repair, replacement and/or evaluation (see comments below)
    Condition of laundry facilities: Appeared serviceable
    Gas supply for laundry equipment present: Not determined
    240 volt receptacle for laundry equipment present: Yes
    46) Minor deterioration or damage was found in the tiled shower enclosure, including broken, cracked tile. A qualified contractor should evaluate and repair as necessary. Note that damage to the wall or other structures behind this tile may be found upon further evaluation, and additional repairs may be needed.
    47)   Leaking or dripping was found at the bathtub spout at location #A. A qualified plumber should evaluate and repair as necessary.
    48)   The shower diverter valve at location #A was defective. A significant amount of water came out of the bathtub spout when the shower was turned on. Water will be wasted as a result. A qualified plumber should evaluate and replace components or make repairs as necessary.
    49) The bathroom with a shower at location #A didn't have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers.
    50)   The window at location #A won't open. Ventilation may be inadequate as a result. A qualified person should repair as necessary.
    51) The caulk between the tub and the floor, walls at location #A, B was deteriorated. A qualified person should repair as necessary.
     
    Kitchen Return to table of contents
    Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Appeared serviceable
    Condition of dishwasher: Appeared serviceable
    Condition of range, cooktop: Appeared serviceable
    Range, cooktop type: Electric
    52)   Caulk was missing where counters met back splashes. A qualified person should repair as necessary.

    Photo 38  
    CAULK BACK SPLASH IN KITCHEN
     
     
    Interior Rooms / Areas Return to table of contents
    Exterior door material: Wood, Metal
    Condition of exterior entry doors: Appeared serviceable
    Condition of interior doors: Appeared serviceable
    Type of windows: Aluminum, Wood
    Condition of windows: Required repair, replacement and/or evaluation (see comments below)
    Wall type or covering: Plaster
    Condition of walls: Appeared serviceable
    Ceiling type or covering: Plaster
    Flooring type or covering: Carpet, Wood, Tile
    Condition of flooring: Appeared serviceable
    53) Rot or water damage was found at one or more exterior door jambs. A qualified person should evaluate and repair as necessary. All rotten wood should be replaced. This is at shop door
    54)   Some windows that were built to open wouldn't open. A qualified person should evaluate and repair as necessary.
    55)   The weatherstrip around one or more exterior doors was damaged, missing. A qualified person should repair or replace as necessary.
    56)   Thresholds at one or more exterior doors are damaged, deteriorated. A qualified person should repair, replace or install as necessary. front door
    57)   Some sections of flooring had minor deterioration or damage. For example, cracked tile. A qualified person should repair as necessary.
    58)   Minor cracks and/or holes were found in walls in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
    59)   Minor cracks and/or holes were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
    60)   Screens in some windows were missing, not installed.
     

    Photo 3  
    TRIM NEEDS REPAIRS

    Photo 4  
    TRIM NEEDS REPAIRS

    Photo 5  
    THRESHOLD NEEDS REPLACING

    Photo 11  
    CHECK FLASHING & KEEP DEBRIS OFF ROOF

    Photo 13  
    CRACKED WINDOW AT APARTMENT

    Photo 14  
    ROOF ON APARTMENT IN NEED OF REPAIR

    Photo 20  
    FLASHING NEEDS REPAIRS AROUND CHIMNEY

    Photo 22  
    A/C NAME PLATE

    Photo 24  
    MINOR CRACK IN CEILING

    Photo 25  
    TILE CRACKED AT PORCH

    Photo 28  
    PAINT BUBBLED ON WALL IN LIVING ROOM

    Photo 29  
    CEILING CRACKS

    Photo 30  
    CRACKED TILES IN BATHROOMS

    Photo 31  
    CRACKED TILES IN BATHROOMS

    Photo 32  
    GFCI OUTLET DOES NOT WORK

    Photo 33  
    CRACKED TILES IN BATHROOMS

    Photo 34  
    CRACKED TILES IN BATHROOMS

    Photo 36  
    HOLE AND PAINT PEELING IN 2nd BEDROOM

    Photo 37  
    STOVE

    Photo 39  
    CRACKED TILES IN KITCHEN

    Photo 40  
    ROTTEN WOOD AT DOOR TO WORKSHOP

    Photo 42  
    ELECTRICAL PANEL IN APARTMENT HAS OPEN SLOTS

    Photo 43  
    OLD WOOD ROT IN ATTIC IN APARTMENT, DRY

    Photo 44  
    SCREEN ON VENT NEED TO REPLACED IN ATTIC OVER APARTMENT

    Photo 45  
    HOLE AND CRACK IN CEILING IN APARTMENT

    Photo 46  
    UNKNOWN HOLE IN ATTIC IN MAIN HOME

    Photo 48  
    DUCTS NEED TO BE RE WRAPPED

    Photo 50  
    ELECTRICAL BOX LOOSE

    Photo 51  
    DUCTS NEED TO BE RE WRAPPED
     

     
    Done By Don Mazza / A-Z Home Inspections